Moeller Bimet
3" DUO-TEMP, REMOTE/LOCAL READING DIAL THERMOMETERS
The DUO-TEMP instrument consists of a 3" shock and vibration resistant BIMTE thermometer and a rare metal remote reading temperature detector (RTD) or thermocouple. Both elements are installed in a single thermowell. The RTD can be wired to a single remote readout or to a selector switch to provide multiple location termperature reading. Although standard units are described here, variations in materials and design can be provided on special order to meet unique specifications.
Features
- Weatherproof, fume-proof case with gasketed removable bezel, all 18-8 stainless steel construction. Gasket is Buna N.
- External Calibration - simple zero reset at back of case on all models.
- Stainless steel stems with all joints welded.
- Anti-parallax scale with frosted aluminum dial and black easy reading numbers and graduations. Black finished, balanced pointer.
- BIMET helix - low mass, single coil is silicone dampened to limit pointer oscillation and accelerate heat transfer.
- Accuracy within 1% of included range.
- Clear, Extra Heavy glass front is standard. Plastic crystals are also available.
- Bayonet style removable bezel.
- Field replaceable RTD or thermometer.
- Supplied with 304SS thermowell which is rugged but permits extreme sensitivity to temperature changes. Sensing unit mounts in well with union swivel nut.
- RTD connector is adjustable horizontally to 360º.
- Weld-in or flanged thermowells are also available on special order.
Standard RTD units are equipped with 100 ohm platinum detector. Nickel or copper RTD are also available on special order. Consult factory for details.
Standard Ranges /
|
Scale Divisions
|
Dual Scale Dial
|
0-200ºF 2ºF
|
20-240ºF 2ºF
|
0-250ºF 2ºF
|
0-250ºC 2ºF
|
50-300ºF 2ºF
|
-20-120ºC
|
Other ranges and scale divisions available on special order. Please consult factory.
Connector Options
- Miniature twist lock connector box (See Fig. 1) with totally enclosed screw terminal connections.
Two section microphone plug type connector with snap lock for secure connection, yet is easily seperated
Thermocouple type junction box for totally enclosed and weatherproof screw terminal junction.
Part Numbering System
When ordering specify: Temperature range, material (30422 is standard), and design for thermowell socket and the following typical model number designation:
D -
|
3 -
|
L -
|
2 -
|
1 -
|
P
|
Duo-Temp Design
|
Dial Size
|
Dial Connectoin (Lower)
|
Insertion Depth (A)
|
RTD Connector (1-Twist-Lock)
|
Platinum RTD
|
When ordering replacement parts describe the specific part required plus the complete original part number of the total unit.